XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.

16.3.3 System-stopped maintenance

1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff all the physical partiti ons.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the crossbar unit requiring
maintenancefrom the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the power supply unit of the crossba r box
requiringmaintenance.
For details, see "5.5.2 Removing the power cord."
16.4 Removing a Crossbar Unit
Thissectio n describes the procedure for removing a crossbar unit.
Enablethe removal of the crossbar box before attempting to remove it. For details,
see "16.3 Enablingthe Removal of a Crossbar Unit."
Chapter16 Maintainingthe Crossbar Units of the Crossbar Box 301