Table3-3 Predictiveself-repairin g messages (continued )
OutputDisplayed Description
Nov1 163020 dt88-292 REC-AC TION
Schedulea repair procedure to replace the affected
device.UseNov 1 163020 dt88- 292 fmdump -v –u
EVENT_IDt o identify the device or contact Sun for
support.
REC-ACTION: Brief description of
thecorrective action the sy stem
administrator should apply
XSCF> setlocator -b 1 blink

3.3.7 Identifying the location of the chassis requiring

maintenance

Executethe setloc ator command to identify the location of the chassis requiring
maintenance by causing the CHECK LED on the operation panel and the CHECK
LED(locator) on the rear panel to blink.
1. Logi n to the XSCF shell.
2. Executethe setlocator command to blink the CHECK LED of the chassis
requiringmaintenance, and determine its location.
TheCHECK LEDs on the operation and rear panels blink.
Anexec ution example in which the chassis requiring maintenance is the master
chassisi ssh own below. When specifying a different chassis such as BB#01, set
"setlocator-b 1 blink."
Fordetails on where to find and how to check the CHECK LEDs, see "2.3
Checking the LED Indications."
3.4 Downloading Error Log Information
Thissection describes the operation for downloading error log information.
Todownload error log information, use the XSCF log fetch function. The XSCF unit
hasa maintenance USB port so that maintenance information such as error logs can
beobtained easily.
For details, see "12.1.15 Saving a log to a file with snapshot" and "12.1.16 Saving a
logto a local USB device" in the Fujitsu M10/SPARC M10 Systems System Operation
and Administration Guide.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 201340