Caution - To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF> showlogs error
XSCF> replacefru
24.2.3 Precautions for replacement
Notethe foll owing points when replacing a crossbar cable (electrical):
■Replacec rossbar cables (electrical) in pairs.
24.3 Enabling the Removal of a CrossbarCable (Electrical)Thissection describes the preparations that must be completed prior to removing the
crossbar cables (electrical). The preparation procedure differs depending on the
maintenancetype as follows:
■Inactive/Cold maintenance
■System-stopped maintenance
24.3.1 Inactive/Cold maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical partition requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013382