ND-20292
CHAPTER 3
APRIL, 1990
MEMORY BLOCK 2C8 - EXTERNAL RINGING CONTROL ASSIGNMENT
1. Go off line.
2. Depress F2, then F8.
3. Depress F18.
4. Dial the number of the External Ringing Control
EXT R I NG 1
circuit being assigned (l-4).
Example: Ext Ring 1. (See Note 11.
INTERVALX
5. Dial the number of the desired ringing interval
E X T R I NC
(l-5) to be assigned to this External Ringing I N T E R v A L 2
Control circuit. Example: Interval 2. (See Note 2).
6. Depress Ll to L8 to assign the appropriate Trunk Groups to the External Ringing Control circuit selected.
(See Note 31.
7. Depress ENTER key. (See Note 41.
8. Repeat steps 5- 7 for all subsequent External Ringing Controls to be assigned, or depress TEL #
key
to
program a specific External Ringing Control circuit.
9. Depress the SPKR key to go back on line.
OPERATION 1 MD -+ DISPLAY
OF F -LINE (X-XX)
PROGRAM MODE
SYS. GROUP
EXT RI NG
NO. 1
-.-‘jl
1
‘.
EXT R I NC 2
INTERVAL2
300 - 120