JOB SPECIFICATION INSTRUCTIONS

FOR MEMORY BLOCKS 4E-4, -5, AND -6 TLI INITIALIZED VALUES

ITEM

MEMORY

 

 

4E-l

 

IBLOCK

I

 

 

 

 

 

ITEM

PAUSE

PRE PAUSE

CO ANSWER

CO RELEASE

 

TIME

TIME

DETECT

DETECT

DEFAULT

1000 Ins.

3 see.

520 mS.

520 mS.

DESCRIPTION

01DURATION OF FORCED GROUND

BETWEEN PULSED DIGITS.

02LAPSED TIME BEFORE SENDING PULSED DIGITS TO CO AFTER DISTANT END GOES OFF-HOOK.

03 MINIMUM TIME INTERVAL AFTER THE CALLED PARTY ANSWERS BEFORE A CONVERSATION MAY START.

ENTRY

0 - 7000 mS. (500mS. INCREMENTS).

0 - 12 SECONDS (O-2 SECONDS IN 500 mS. INCREMENTS;

2-12 IN 1 SECOND INCREMENTS).

0 - 1820 mS. (130mS. INCREMENTS).

4E-5

MINIMUM TIME AFTER HANGING UP BEFORE

- M LEAD RECOGNIZES A DISCONNECT FROM THE CO.

05TIME DURATION LAPSED BEFORE RECOGNIZING AN OFF-HOOK CONDITION FROM THE CO WITH A

DELAY OR WINK SIGNAL.

0 - 1820 mS. (130mS.

INCREMENTS).

 

FOR WINK

START =

O-1820mS.

(130 mS.

 

 

INCREMENTS)

FOR DELAY

DIALING

= O-420mS.

(30mS.

 

 

INCREMENTS)

06 LAPSED TIME AFTER LOCAL STATION ANSWERS BEFORE A VOICE PATH IS ESTABLISHED.

180 mS.

300 mS.

O-12 SECONDS (FROM O-2 SECONDS IN 500 mS.

INCREMENTS; FROM 2-12 SECONDS IN 1 SECOND INCREMENTS).

f;77LENGTH OF WINK SIGNAL SEND TO THE DISTANT LEND.

08 LENGTH OF DELAY SIGNAL SEND TO THE DISTANT END.

09 THE LENGTH OF TIME, IN SECONDS, THAT THE

4E-6

ISYSTEM WILL MONITOR THE CENTRAL OFFICE LINE FOR RECEIPT OF A WINK SIGNAL.

10

0 LENGTH OFTIME THE SYSTEM WILL NOT ORIGINATE AFTER HANGING UP.

11

0 WHEN USING A TANDEM PORT, TIIE MAXIMUM TIME BEFORE THE VOICE PATH IS ESTABLISHED, AFTER DIALING THE FIRST DIGIT, AND BETWEEN EACH DIGIT DIALED.

30mS. - 450 mS. (30mS. INCREMENTS)

0 - 4200 mS. (300mS. INCREMENTS)

1 - 14SECOND ORm(l-14SECONDSIN 1 SECOND INCREMENTS).

1 - 9 SECONDS

2 - 28 SECONDS OR m (2-28 SECONDS IN 2 SECOND INCREMENTS).

300-320