ETI NUMBER: DT-006

5.2Transferring a call from handset to Speakerphone; or Speakerphone to handset:

5.2.1To transfer a call from the Multiline Terminal handset to the Phonebeam Speakerphone, depress the “ON” key of the Speakerphone (or switch the Speakerphone remote microphone unit to the “ON” position) and then hang up the Multiline Terminal handset.

5.2.2To transfer a call from the Phonebeam Speakerphone to the Multiline Terminal handset, lift the Multiline Terminal handset and turn off the Phonebeam Speakerphone.

6.PROCEDURE

6.1Turn the Multiline Terminal upside down (face down) ..and locate the access panel on the bottom of the Multiline Terminal, refer to-Figure 1.

6.2Disconnect the modular line cord from under the telephone at the RJ-1lC/W jack.

6.3Disconnect the modular handset cord from the lower housing.

6.4Slide the directory out of the way (Not required for ETE-6-O or ETE-16-O Multiline Terminal).

6.5To remove the access panel, perform only the step that applies, either 6.5.1 or 6.5.2 (Refer to Figure 1).

6.5.1ETE-6D-0, ETE-16D-0, or ETE-16K-1 Multiline Terminal; Inset-t a flat screwdriver blade into notched opening (shown as A) and apply light upward pressure until the access panel clears the front lip, at the same time apply pressure (toward you) at the rear of the pedestal (shown as B) until the access panel moves toward you. Remove panel.

6.5.2ETE-6-0, or ETE-16-O Multiline Terminal; Depress the flexible notched tab (shown as C) on the access panel and apply upward pressure. Remove panel.

NOTE

Do not discard removed access panel; save forpossible future use.

6.6Locate the four pin connector and jack labeled HAND (as seen through the access view of the Multiline Terminal housing). Unplug this connector and extend it out from the housing access opening.

6.7Set the SW2 DIP switches, on the ADA-E unit, as shown in Table 1 of Figure 2. Place the jumper across pin ST2 and the center pin. Set SW1 to the MAKE position.

6.8Using the connecting cable from the Speakerphone, make the wiring connections shown in Figure 2. If necessary, use a section of the clear plastic tubing provided in the ADA-E kit to insulate the connections. Individually insulate the unused leads.

6.9Locate and insert the four pin connector ended harness from the ADA-E unit into the jack labeled HAND on the Multiline Terminal.

6.10Locate and insert the eight pin connector ended harness from the ADA-E unit into the jack labeled ADA on the Multiline Terminal.

6.11Insert the four pin connector ended harness (removed in step 6.6) into the four pin jack, CN3, located on the ADA-E unit.

1 J

2 of 7