ETI NUMBER: OS-006

6.PROCEDURE

6.1Disconnect the line cord of the Dterm II telephone from the RJll wall jack.

6.2Plug the Dterm II telephone line cord into the T-adapter jack marked “PH”

6.3Insert the Companion 45 line cord into the jack in the base of the unit. Insert the other end of Companion 45 line cord into the T-adapter jack marked “HF”.

6.4Plug the l-adapter in the RJl 1 wall jack.

6.5 Plug the Transformer into a local 1lo-120V ac outlet. Refer to Figure 1. for connection of Companion 45 to

a Dterm Telephone.

t---.

 

AC OUTLET

I I

 

0

Step6.5

A

 

TRANSFORMER

,

_ ,’

OTERM TELEPHOE

COMPANION 45 (NT1 LO6

Figure 1. Connecting Companion 45 to a Dterm II Telephone (ETE-l-2 or ETE-lHM-2)

6.6Test the following steps for normal operation.

A. Press the “ON” button on the Companion 45 (dial tone should be heard and the red LED should light).

B.Place a call using the Companion 45 dial pad. After the call is established, pick up the Dterm handset

(the Red LED will

go off)

and verify

proper communication.

Transfer the call back to the Companion

45 by pressing the

“ON”

button (the

Red LED will blink).

 

C.Release the call by pressing the “RLS” key, the line connection and LED will go off.

2OF2

Page 738
Image 738
NEC nd-20292 manual ETI Number OS-006, Procedure