4.16
4.17
4.18
4.15.5
4.15.6
4.15.7
4.15.8
ET1 NUMBER: MK-006
DATE: FEBRUARY, 1988
Solder two .OlpF
ceramic
disk capacitors to the solder side of the
handset connector
designated HAND on the main PC board; one capacitor across pins
1
&
2 and the other across
pins 3 & 4. Use plastic sleeving over the capacitor leads. KEEP THE LEADS AS SHORT
AS POSSIBLE. (For ETE-GD-1 or ETE-16D-1 Terminals, see Figure 3. For ETE-16K-1
Terminal, see Figure 4.)
Position the PCB board in place and secure with six screws (ETE-16K-1
screws) (Removed in 4.15.4).
Connect two flat ribbon cables to the PCB connector (Disconnected in 4.15.3).
Terminal,
connect the
speaker plug to the speaker connector.
has only three
On ETE-16K-1
Position the volume and display intensity slide control handles in place; ensure the modular
line cord connector and hookswitch levers are positioned properly. Join the upper and lower
housings; tighten two captive screws.
Slide the Multiline Terminal directory back into place.
Install the handset and modular line cords into the Multiline Terminal, and RJ-13CW jack.
Ensure that the station operates normally. If RF1 is still present, contact your local NEC America
Inc., SBS Field Support Engineer.
Soft3