NEC AMERICA, INC.

BUSINESS SYSTEMS DIVISION

NFORMATlOt

ET1 NUMBER: MK-009

DATE: MAY, 1988

INSTALLATION OF TELTONE M-l 06

REMOTE SERVICE ACCESS UNIT FOR DISA

1.DESCRIPTION

This Engineering Technical Information (ET11 Bulletin describes the steps necessary to connect a Teltone

.M-106 Remote Service Access Unit to an Electra Mark11 system for providing Direct Inward Service Access

(DISA). When connected to a non-dedicated line, this adaptor can function as a special off-premises

extension of the Electra Mark11 providing complete access to single line station features. With the unit

turned off via a remote night transfer switch, calls directed to the adaptor terminate at the Mark11

attendant station. When connected to a dedicated line, the adaptor functions primarily as a security device,

limiting access to the single line station features to off-premise callers using a security code.

2.LIMITATIONS

2.1Must be connected to a single line port and DTMF signaling provided.

2.2Cannot be used with party lines or coin lines.

3.PARTS REQUIRED

NOTE: The installation procedure for all models listed is identical. This procedure covers the installation

of Model _M-106-07 that comes equipped with modular line cords. If any other model is installed, modular line cords must be locally acquired.

3. L Remote Service Access Cnit, Model M-106 ordering options:

3.1.1M-106-01 (48V unit with Lorain repeater).

3.1.2_M-106-02 (24V unit with Lorain repeater).

3.1.3M-106-05 (48V unit without Lorain repeater).

3.1.4M-106-06 (24V unit without Lorain repeater).

3.1.5.M-106-07 (24V unit with Lorain repeater and two 7 foot, 8 position modular cords).

3.2Two modular jacks, type RJ-34X

3.3Four conductor station cable (26 AWGl long enough to connect the RJ-34X jacks to the MDF

3.4 Valcom

-24

Volt, 1 Amp.

power

supply

Model

VP

1024, or

equivalent.

(1 to

3 remote

access units can be

supplied with each power supply; approx. 300 mA are required for each remote unit).

 

NOTE:

An

equivalent

48 volt

power

source

must

be used

if a 48 volt

Teltone

unit is

installed.

1 of 6