4.4 When called party answers, lift the handset and converse.
4.5 After call is established, manually turn OFF the Autodialer by depressing its ON/OFF button.
5. PROCEDURE
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
Turn the Multiline Terminal upside down (face down) and locate the access panel on the bottom of the
Multiline Terminal, refer to Figure 1.
Disconnect the modular line cord from under the telephone and from the RI-1 lC/W jack.
Disconnect the modular haz:dset cord from the lower housing.
Slide the directory out of the way (Not required for ETE-6-1 Multiline Terminal)
Removal of access panel (Perform
only
the step that applies, either 5.5.1 or 5.5.2) Refer to Figure 1.
5.5.1 ETE-GD-1, ETE-IGD-1, or ETE-16K-1 Multiline Terminal; Insert flat screwdriver blade into
notched opening (shown as A) and apply light upward pressure until access panel is cleared of
the front lip, at the same time apply pressure (towards you) at the rear of the pedestal (shown
as B) until the access panel moves towards you. Remove panel.
5.5.2 ETE-6-1 Multiline Terminal; depress spring loaded notched tab (shown as C) on the access
panel and apply upward pressure. Remove panel.
NOTE: Do not discard removed access panel. While it will not be used at this time, save for possible
future use.
Locate the eight pin jack labeled “ADA”, as seen through the housing access opening of the -Multiline
Terminal housing.
Unplug the four pin connector ended harness (labeled HAND) and extend it out from the housing
access opening, of the Multiline Terminal.
Set the Dip switches on the ADA-E unit as shown on Table 1 (See Figure 3). Place the jumper strap
across ST2 and the center pin. Set SWI to the BREAK position.
Remove approximately 3 inches of outer insulation from both ends of the 4 conductor station wire cable
and strip off + inch of wire insulation from each of the four wires; solder or crimp a spade lug to each
wire
end.
.Make the RJ-35X connections as indicated in Figure 3 using the prepared 4 conductor station wire
cable. Use one of the two spade tipped jumper wires provided with the ADA kit to make a connection
between Tl and T5; connect the other jumper wire between T2 and T4 on the ADA-E unit.
Locate and insert the four pin connector ended harness from CNl on the ADA-E unit into the jack
labeled HAND in the Multiline Terminal.
Locate and insert the eight pin connector ended harness from CNl and CN2 on the ADA-E unit into
the jack 1abeled”ADA” in the Multiline Terminal.
Insert the four pin connector ended harness (removed in step 5.7) into the four pin jack, CK3, located on
the ADA-E unit.
2of6