NEC AMERICA, INC.

BUSINESS SYSTEMS DIVISION

ET1 NUMBER: MK-003

DATE: JULY 7.1987

GENESIS GENIE VOICE MAIL SYSTEM CONNECTION

PROCEDURE

1. DESCRIPTION

This Engineering Technical Information (ET11 Bulletin describes the procedure for connecting the Genesis GenieVoice Mail System to the Electra Mark11 system via the VMI-E ETU.

NOTE: Before undertaking this procedure, the installer should be famiiiar with the Genesis Genie, Technical reference manual and Chapter 8 of the Electra Mark11 Installation Service Manual.

2.PARTS REQUIRED

2.1VMI-E ETU (An MFR-EA ETU and an RSG-E unit associated with the CCU in which the VMI-E ETU is installed are also required).

2.2Genesis GenieVoice Mail System (Including the Technical Reference Manual and the System MMgnagers Guide 1.

2.3A serial computer terminal (The NEC PC8201A or PC8300 portable computers are recommended).

2.4RS232C Null Modem cable (Pins 2 and 3 reversed).

2.5Modular Line Cords (21, RJ1 lC/W connectors and cable.

3.OPERATION

After installation and programming are completed, users of the Electra Mark11 will be able to access the Genie system from any internal extension either by Hunt Group Access (Default Code 63) or by dialing one of the VMI extensions directly.

Once a call is placed into the Genie system, the user is directed by the audible menu prompts of the Genie on how to access the various features available. For a complete explanation of the features available with the Genesis Genie Voice Mail System, refer to the Genie System User’s Guide and System Manager’s Guide.

4.PROCEDURE

4.1Connection

4.1.1Install the VMI-E ETU in an available interface slot, in a CCU which is supported by an RSG-Eunit.

1 of 3