ET1 NUMBER: MK-012
DATE: DECEMBER
1988
6.3.5 Connect the 12-14V power pack into the AEC 212 first, and then into the
nearest AC power outlet.
6.3.6 Using the built-in microphone, or a carbon type handset, record the desired
announcement as indicated in the AEC 212 Plus owners manual. For
maximum effectiveness, it is recommended that the message be limited to
a maximum of 15 seconds followed by a silent period of 2 seconds.
6.4 Electra MarkII system programming (Refer to the Electra Mark11 Installation
Manual)
6.4.1
6.4.2
6.4.3
6.4.4
6.45
6.4.6
6.4.7
Assign individual trunks for DIT or ANA o
and 2B4. eration in Memory Blocks 2B3
(Delay Announcement is availab e for DIT or ANA trunks only).
P
Assign the Delay Announcement feature to each required DIT or ANA
trunk in Memory Block 2C5.
Assign desired time delay between incoming ring signal recognition and
the start of the Delay Announcement to the calling party in Memory Block
2D2, using line key 6. This timer is adjustable from 1 to 99 seconds. Use of
the system default value (20 seconds) is recommended.
Assign the desired Delay Announcement Auto Release Timer in Memory
Block 2D1, using line key 3. This timer determines how long an outside
line will remain connected to the announcement device after encountering
either a busy signal or no answer from a Hunt Group. If the outside line
can provide a remote disconnect signal, the remote disconnect will
supercede this timer if the remote disconnect signal occurs before the timer
elapses. Timer ranges from 10 to 990 seconds and can be disabled. Default
value of 600 seconds (10 minutes) is recommended.
,.
Select one of the ECR-E ETU relays to activate the announcement unit in
Memory Block 2C9. Use of relay number 10 is recommended. (See Figure
1)
If station Hunt Groups are required, use Memory Blocks 3B5 thru 3B8 to
assign the required parameters.
Activate the Day and Night Delay Announcement feature from an idle
Attendant station as follows:
6.4.7.1 Depress CNF key.
6.4.7.2 Depress line key 9 (for Day Mode) and 10 (for Night Mode) (Both
LEDs illuminate).
6.4.7.3 Depress CNF key (to return ON LINE).
7. TESTING
After installation and programming is completed, test the operation as follows:
4 of 6