5.9Connect one end of the two conductor wire to the screw terminals on the provided power supply. Connect the other end of the two conductor wire to the (BROWN/WHITE and WHITE/BROWN) of the Companion II Speakerphone (See Figure 2).

5.10Using the connecting cable from the Speakerphone, make the wiring connections shown in Figure 2. If necessary, use a section of the clear plastic tubing provided in the ADA-E kit to insulate the connections. Individually insulate the unused leads.

5.11Locate and insert the four pin connector ended harness from the ADA-E unit into the jack labeled HAND on the Multiline Terminal.

5.12Locate and insert the eight pin connector ended harness from the ADA-E unit into the jack labeled ADA on the Multiline Terminal.

5.13Insert the four pin connector ended harness (removed in step 5.6) into the four pin jack, CN3, located on the ADA-E unit.

5.14Install the ADA-E unit with the component side down ensuring the wires are not pinched. Secure the ADA-E unit to the terminal housing with the screw provided as shown in Figure 3a. (ETE-6D-0, ETE- 160-0, or ETE-16K-1) or 3b (ETE-6-0, or ETE-16-O).

NOTE 3

Two access panels are provided with the ADA-E unit; a narrow panel to be used with ETE-6-O or ETE-16-O Multiline Terminals and a wide panel to be used with all other terminals. Ensure the correct access panel is used.

5.15Route the Speakerphone wires (already connected to the ADA-E unit) through one of the two notched grooves on the access panel. Install the access panel.

5.16Slide the Multiline Terminal directory back into place, if required.

5.17Reinstall the handset line cord onto the Multiline Terminal.

5.18Plug the AC adaptor to the Speakerphone first, then plug it into a convenient AC outlet.

5.19Refer to the Speakerphone’s user guide and test both the Speakerphone and the Multiline Terminal for proper operation.

3 of 7

Page 769
Image 769
NEC nd-20292 manual ETI Number DT-005