ETI NUMBER: DT-007

 

 

 

 

 

 

 

 

..

4.5 From one end of the two conductor wire (Step

3.3) remove

approximately

4 inches of

outer insulation

and

.“,

strip off + inch of the inner insulation

from each

of the two wires. To

each conductor

fasten one

of the

 

spade lugs locally provided, either by

soldering

or

crimping.

 

 

 

 

 

4.6To remove the access panel, perform only the step that applies, either 4.6.1 or 4.6.2 (Refer to Figure 1).

4.6.1ETE-6D-0, ETE-16D-0 or, ETE-16K-1 Multiline Terminal; Insert a flat screwdriver blade into notched opening (shown as A) and apply light upward pressure until the access panel clears the front lip, at the same time, apply pressure (toward you) at the rear of the pedestal (shown as B) until the access panel moves toward you . Remove panel.

4.6.2ETE-6-O or ETE-16-O Multiline Terminal; Depress the flexible notched tab (shown as C) on the access panel and apply upward pressure. Remove panel.

NOTE:

Do not discard removed access panel; save for possible future use.

4.7Locate the four pin connector and jack labeled HAND (as seen through the access view of the Multiline Terminal housing). Unplug this connector and extend it out from the housing access opening.

4.8Set the SW2 Dip switches, on the ADA-ER unit, as shown in Table 1 of Figure 2. Place the jumper across pin ST1 and the center pin. Set SW1 to the BREAK position.

4.9Make the wiring connections as indicated in Figure 2. If necessary, use a section of the clear plastic tubing provided in the ADA-ER kit to insulate the connections.

4.10Locate and insert the four pin connector ended harness from the ADA-ER unit into the jack labeled.HAND on the Multiline Terminal.

4.11Locate and insert the eight pin connector ended harness from the ADA-ER unit into the jack labeled ADA on the Multiline Terminal.

4.12Insert the four pin connector ended harness (removed in step 4.7) into the four pin jack, CN3, located on the ADA-ER unit.

4.13Install the ADA-ER unit with the component side down ensuring the wires are not pinched. Secure the ADA-ER unit to the terminal housing with the screw provided as shown in Figure 3a [ETE-6D-0, ETE-16D-() or, ETE-16K-I] or, 3b [ETE-6-O or, ETE-16-O]

NOTE

Two access panels are provided with the ADA-ER kit; a narrow panel to be used with ETE-6-O or ETE-16-O Multiline Terminals, and a wide panel to be used with all other terminals. Ensure the correct access panel is used.

4.14Route the locally provided cable (already connected to the ADA-ER unit) through the cable exit grooves on the access panel. Install the access panel. (Refer to Figure 3 for cable exit groove location)

4.15Slide the directory back into place, if required.

4.16 Reinstall the handset and modular line cords onto the Multiline

Terminal.

--

2 of 7

Page 782
Image 782