ND-20292
CHAPTER 2
APRIL, 1990
-
J8 (AC OUT) J7 J6 J5 (RSG) J4 (DC IN)
-
0
o PSE-AD-1 RSG-E
Figure 200-10 Front View of ESE-32B-1 CCU
c.
D.
E.
F.
G.
Unscrew the two screws located on the top front of
the CCU, then remove the top panel. Place the
panel and screws aside for later reinstallation.
Unscrew the two screws located on the bottom
front of the CCU, then remove the base panel.
Place the panel and screws aside for future
reinstallation.
Locate the two mounting screws on the upper rear
of the CCU (holding the upper mounting bracket to
the CCU), remove the two screws and the bracket.
Remove the two mounting screws holding the
lower mounting bracket to the base panel.
Use the template provided with ESE-32B-1 CCU to
layout CCU(s) in position. Install eight locally
provided fasteners appropriate for wall mounting
in positions shown on the template. CCU(s) must
be mounted correctly for proper operation. Mount
the base panel onto the lower bracket using the two
screws removed in step F. (See Figure 200-11).
H. The ESE-32E-1 CCUs are equipped with one wall
mounting bracket. This bracket must first be
detached from the CCU to properly wall mount the
unit.
I. When the first ESE-32E-1 CCU is to be installed,
repeat step B. Locate the two mounting screws in
the upper rear of the CCU, remove the screws and
bracket. Also, remove the two screws located on
the top front of the CCU.
J. Mount the metal bracket using four locally
provided fasteners as outlined with the template.
Refer to Figure 200-l 1.
K. Ensure the hooks provided on the top rear of the
ESE-32B-1 CCU are fully seated within the open
slots on the bottom rear of the ESE-32E-1 CCU.
Install the wall mounting metal brackets as shown in
Figure 200-11, using the eight locally provided
fasteners. After mounting the ESE-32E-1 CCU onto
the ESE-32B-1 CCU, secure them using the four
screws removed in step I, as shown in Figure 200-13.
L. When the second ESE-32E-1 CCU is installed, it
should be attached in the same manner as the first
ESE-32E-1 CCU.
M. When the third ESE-32E-1 CCU is installed, it
should be attached in the same manner as the
ESE-32B-1 CCU
Using the open slots provided on the back panel of the
CCU, mount the CCU to the knobs of the upper bracket
and onto the base panel. Ensure the upper bracket
knobs are fully seated within the open slots of the
CCU. Tighten the screws from above the CCU to
securely attach the CCU to the upper bracket knobs,
reinstall the two screws removed in step D, as shown in
Figure 200-12.
200- 19