AlECAmerica Inc. Switchinq Terminals Division

Engineering Technical Information

SOFT-COM SCOUT JR. CALL ACCOUNTING SYSTEM CONNECTION PROCEDURE

ELECTRA MARK11

ETI NUMBER: MK-018 DATE: APRIL, 1990

1.DESCRIPTION

This Engineering Technical Information (ETI) Bulletin describes the procedure for connecting the Soft-Corn Scout Jr. Call Accounting System to the Electra Markll system via the SMDR-E ETU. This Call Accounting Systemconsists only of software that must be stored on a personal computer hard disk.

NOTE: Before undertaking this procedure, the installer should be familiar with the Soft-Corn Scout Jr. Technical reference manual and Chapter 2 of the Electra Markll Installation Service Manual.

2.PARTSREQUIRED

2.1SMDR-E ETU.

2.2Soft-Corn Scout Jr. (Version 4.3 or higher) Call Accounting System. This system can support a maximum of eighty (80) extension numbers.

Soft-Corn Inc.

140 West 22nd Street New York, NY 10011 (2 12) 242-959s

2.3RS-232C Straight Cable with male connectors at both ends.

2.4An NEC Powermate or IBM compatible computer with hard disk. The following are the basic requirements: 640K RAM

Communications Port

Hard Disk - 20 Mbytes Minimum

) 5 Mbytes for storing the Scout Jr. resident program. ) 10 Mbytes allows 10,000 calls to be stored.

One 5-l/4” or 3-l/2” Floppy Disk Drive Display/Printer Interface Card Monitor

MS-DOS Version 3.1 or higher

(Refer to the Scout Jr. manual for additional computer hardware requirements).

2.5Serial or parallel printer (to be used for the printing of call record reports). This printer must be connected to the computer.

3.OPERATION

After installation and programming are completed, system managers of the Scout Jr. system will be able to print call record reports showing incoming and outgoing calls by extensions, departments, trunks, account codes, etc. In addition, the Scout Jr. allows custom reports to be printed for programmable variables.

lOF3

Page 824
Image 824
NEC nd-20292 manual AlECAmerica Inc. Switchinq Terminals Division