America Inc. Switchinq Terminals Division

Engineering Technical Information

AEC TWO CHANNEL

ANNOUNCEMENT MACHIN E

ELECTRA MARK11

ETI NUMBER: MK-012A DATE: APRIL, 1990

REVISED FROM: MK-012 DECEMBER, 1988

NOTE: This ETI is revised.from MK-012 and provides information for a 2 channel Delay Announcement with Electra Markll - Series300 Software. This ETI is also applicable for Series 300 Software.

1.DESCRIPTION

This Engineering Technical Information (ETI) Bulletin describes the steps necessary for the installation of an AEC Messenger, Model 212 Plus, dual line announcer for operation with an ECR-E ETU. The delayed announcement feature may be desirable when using a Hunt Group in conjunction with DIT or ANA to provide UCD. Any time all stations in the Hunt Group are busy or unable to answer, the Delay Announcer can be used to provide one (1) or two (2) delay announcements instructing callers to wait or call back later.

2.LIMITATIONS

2.1For only one (1) delay announcement, ignore information pertaining to the second delay announcement. Station BGM channel 1 is the same as MOH. Only one each of the items mentioned in 3.3 through 3.7 will be required. In addition, in memory block 2D1, if Line Key 2 is changed to any number other than 99, both station BGM channels are same as MOH.

2.2If two (2) delay announcements are used, both station BGM channels will be the same as MOH

3.PARTS REQUIRED

3.1ECR-Eand CPU-EC4 ETUs or higher.

3.2AEC - Messenger, Model 212 Plus. This part can be ordered from:

AUTOMATION ELECTRONICSCORPORATION

11501 Dublin Blvd., Dublin, CA 94568

Tel : l-800-232-4653

California and Alaska (415) 828-2880

3.3Two RJ-31X Modular Jacks.

3.4Two 8 pin modular cables approximately 7 feet long.

3.5Two 100 Ohm, ) - watt carbon film resistors.

3.6Two RCA male audio plugs with audio shielded cable.

3.7Two lengths of 2-pair station cable.

A.One piece of 2-pair cable is connected from the Electra Markll Frame Ground to the RJ-31X modular jacks that are located near the AEC (model 212 Plus).

B.The second piece of 2-pair cable is connected from the ECR-E ETU card to the Electra Markll Frame Ground.