ND-20292

 

 

 

 

 

CHAPTER 8

 

 

 

 

 

APRIL, 1990

‘.

 

 

 

 

 

VMI-E ETU SifznalTimina Parameters (Memorv Blocks 2D2.4B8 and 4B9)

 

 

PARAMETER

MINIMUM

MAXIMUM

DEFAULT

INCREMENTS

MEMORY

BLOCK

 

 

 

 

 

Voice Mail Automatic Dial

1 sec.

99 sec.

2 sec.

1 sec.

2D2

Send Start

 

 

 

 

 

Hookflash Start Time (HFS)

100 mS.

800 mS.

300mS.

50 mS.

4B8

Hookflash End Time (HFE)

100 mS.

2200 mS.

1000 mS.

100mS.

4B8

Bounce Protection Time (BP)

0 mS.

1400 mS.

300 mS.

100 ms

4B8

Pause Time

“ OmS.

7000 mS.

1000 mS.

500 mS.

4B9

Disconnect Time

500 mS.

3300 mS.

1500 mS.

200 mS.

4B9

rnterdigit Interval Time

40 mS.

180 mS.

110 mS.

10 mS.

4B9

DTMF Digit Duration

60 mS.

760 mS.

110 mS.

50 mS.

4B9

800-3

Page 940
Image 940
NEC nd-20292 manual Parameter Minimum Maximum Default Increments Memory Block