ND-20292
CHAPTER 3
APRIL, 1990
MEMORY BLOCK 5B3 - INTERFACE SLOT CHECK
1. Go off line.
OPERATION - AND - DISPLAY
2. Depress F5, then F7.
3. Depress 13.
4. Dial module number (l-4) of the slot to be
checked.
Example: Module 1
OFF-LINE (X.Xx)
PROGRAM MODE
MAINTENANCE1
INTERFACE CHECK
MODULE? SLOT *
INTERFACE CHECK
MODULE1 SLOT?
5. Dial slot number (l-8) for the required slot.
INTERFACE CHECK
Example: Slot 5
(See Note 1 .I
MOD 1 SLOT5 -xxx
6. If the counter value is not to be cleared,
proceed to Step 9.
7. Depress CLEAR key.
8. Depress ENTER key. (See Note 2).
9. Depress SPKR key to go back on line.
INTERFACE CHECK
MOD 1 SLOT5 -000
INTERFACE CHECK
MOD 1 SLOT6 -xxx
300 - 244