ND-20292

CHAPTER 3

APRIL, 1990

MEMORY BLOCK 5B3 - INTERFACE SLOT CHECK

OPERATION

-

AND -

DISPLAY

1.Go off line.

2.Depress F5, then F7.

3.Depress 13.

4.Dial module number (l-4) of the slot to be checked.

Example: Module 1

5.Dial slot number (l-8) for the required slot. Example: Slot 5

(See Note 1.I

6.If the counter value is not to be cleared, proceed to Step 9.

OFF-LINE(X.Xx)

PROGRAMMODE

MAINTENANCE1

INTERFACE

CHECK

 

MODULE?

SLOT

*

INTERFACECHECK

MODULE1SLOT?

INTERFACE

 

 

CHECK

MOD

1

SLOT5

-xxx

7.

Depress

CLEAR

key.

 

INTERFACE

 

 

CHECK

 

 

 

 

 

MOD

1

SLOT5

-000

8.

Depress

ENTER

key.

(See Note 2).

INTERFACE

 

 

CHECK

MOD

1

SLOT6

-xxx

 

 

 

 

 

9.Depress SPKR key to go back on line.

300 - 244

Page 327
Image 327
NEC nd-20292 manual Memory Block 5B3 Interface Slot Check, OFF-LINEX.Xx, MOD SLOT5, Xxx, MOD SLOT6