8.2Loosen four screws (2 on top, 2 on the bottom) and remove the CONFER@ unit cover.

a.3 Position the CONFER@ unit against a vertical surface. Make sure that the arrow on the power unit’s

shield is pointing up (See Figure 2).

8.4.Using the CONFER@ unit as a template, mark and drill four holes on the vertical surface and fasten the CONFER@ unit to a wall using wood screws or wall anchors.

8.5Connect the 36-pin male connector to the CONFER@ unit (See Figure 2).

9

8

RED

 

 

n

yP?FiiFR

 

 

P%x:R

UP

 

 

 

..

i

 

36-PIN

 

 

CONNECTOR

 

 

CABLE

 

/

BRACKET

 

 

/

 

)$-TO:

MDF

 

RESET

 

 

BUTTON

 

-------(BOTTOM

PCB)

.I

Figure 2. CONFER,3 Unit with cover removed.

8.6Locate the last five CO line pairs on the 66 block and remove the bridging clips

8.7Connect the open end of the 36 pin connector cable to the 66 block, on the KSU side, as shown in

Figure 3. Any spare wires should be insulated and tied back.

8.8Ground the CONFER@ housing to an available ground connection as described in the CONFER’3

Installation Manual.

8.9Plug the CONFER@ unit into the AC outlet and observe that the red power LED on the upper corner of the CONFER@ unit lights.

8.10Depress the reset button located at the lower right hand corner of the CONFER@ board (See Figure 2).

8.11Refer to the installation manual and match each CO line to the CONFER@ unit as described.