ND-20292

CHAPTER 9

APRIL, 1990

C.Proceed to retype the information, line by line, that was included in your previous CONFIGSYS File. After this information has been typed in, type DEVICE =ANSI.SYS and press RETURN.

D.Press (CTRL) Z and RETURN.

E.Reboot the system. (This can be done by pressing (CTRL) (ALT) (DEL) at the same time.)

950.4CREATING A DIRECTORY

A Directory must first be created on either the computer hard disk, or a Double Sided High Density

diskette. A name or code (maximum of eight alpha/numeric characters) for a particular customer site is recommended; (Example: ABC). The following procedure is required to create a Directory:

From the Disk/Hard Drive prompt representing the location where the data is to be stored, type the command “MD\” followed by the Directory file name that is being created. (Example A: > MD\ABC) This will create a Directory file for the location of the system data under “ABC”.

To remove this directory, delete all files in the directory first, then from the A: > prompt, for example, type the command “RD\” followed by the directory name.

950.5REMOTE OPERATION SETUP

From a remote location, you must use the IBM V2.0 of COMLINK software with the RAA to establish communication with the remote site. To establish this

communication, refer to the Electra Mark11 Installation Service Manual, Chapter 9, Section 940.5 (Parts A and B).

After communication with the remote site is established, exit from the COMLINK program to the A: > prompt. This can be done as follows:

1.Press (ES0 key.

2.The screen prompts you if you are calling another system or if you wish to use DATASAVE. Press (ES0 key.

3.The screen then prompts you that you are exiting the RAA emulator. Press any key to exit.

4.You are now at the A > or B > prompt.

5.Proceed with Step 1 of Section 950.6 (Operating Procedures).

NOTE: After any programming is done to the remote Electra Mark11 System with the COMLINK software, you can escape from this program to use the System Data Up/Down Load program by using the same modem connection.

950.6OPERATING PROCEDURES

1.Install the “DATASAVE” diskette into the PC disk drive.

2.To start the program. Enter “Datasave” and press c(Return1 at the A:> prompt if you are using the COMl Port. When the COM2 Port is being used, the following must be entered: “DATASAVE 2” and press t(Return). Display shows:

-.1, i I

c ELECTRA MARK 2 DIGITAL KEY TELEPHONE SYSTEM >

SYSTEM MEMORY UP LOAD /DOWN LOAD

VERSION X.Xx

(C)COPYRIGHT NEC CORPORATION 1990 ENTER DISK DRIVE (AND PATH):

L

900 - 16

Page 958
Image 958
NEC nd-20292 manual System Memory UP Load /DOWN Load