ETI NUMBER: MK-015

Electra Markll Programming

7.4.1A CO line appearance representing the CO port for the Viking products must be assigned to the appropriate stations that will be answering and controlling them. MB 1A can be used for this assignment.

7.4.2Test the Viking W-1000/W-2000 for proper operation in conjunction with the Electra Markll

For configuration 2.3 (Door Release connected to VMI port). See Figure 3.

i-/

7.5.1Determine the location for mounting the Viking RC-2A Remote Touch-Tone On/Off Industrial Controller Door Release. Ensure that there is an indoor 12OV ac.power source nearby.

7.5.2Install the VMI-E ETU in an available interface slot (if a VMI port is not already available).

7.5.3Install the RSG-E Unit in an available RSG slot, in the same or adjacent Electra Markll CCU where the VMI-E ETU is installed, provided an RSG-E Unit is not already installed.

7.5.4Insert the RJll connector end of the modular line cord into the RJ-OUT of the Viking RC-2A Door Release.

7.5.5Insert the other RJl 1 connector into the modular jack representing the available VMI port.

7.5.6Set the Entry (Security) Code (a security code is required before the relays can be

activated/deactivated) of the Viking RC-2A by rotating the dials shown under Entry Code l-2-3.

7.5.7Plug the unit into the nearest 120V ac outlet.

iElectra Markll programming

7.6.1To control the Viking RC-2A Door Release, a * must be sent first; therefore, MB 2A5, Line Key 1 must be turned off.

7.6.2DTMF digit duration must be increased for sending control codes to the Viking RC-2A Door Release. The VMI port that the Viking products are connected to, MB 4B9, Line Keyes 5-8 must be changed to OFF-OFF-ON-OFF.

7.6.3Connect additional equipment that is to be controlled by the Viking RC-2A to contacts A and B. The “shunt” on the RC-2A (representing Normally Closed or Normally Open) may need to be changed (depends on requirements of additional equipment).

7.6.4Test the Viking RC-2A for proper operation in conjunction with the Electra Markll. Testing can be accomplished using the following procedures.

A.Dial station number representing the VMI port.

B.After RC-2A answers, enter * and Entry Code.

C.Enter Command Codes and listen for confirmation tone.

5OF6

Page 692
Image 692
NEC nd-20292 manual 5OF6