ETI NUMBER: MK-018
4. PROCEDURE
4.1
4.2
4.2.1
4.2.2
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.4
Scout Jr. Installation
Load the call accounting software into the computer in accordance with the Scout Jr. manual. Scout Jr.
already contains the switch parameters for the Electra Markll; therefore, choose the item number that
represents the Electra Markll in the switch setup during installation.
Connections (refer to Figure 1)
Install the SMDR-E ETU into an available option slot in a CCU. (Refer to Chapter 2 of the Installation Service
Manual.) . .
Connect one end of the RS-232C cable to the female connector of the SMDR-E ETU. Connect the other end of
the RS-232C cable to a COM Port on the computer.
Electra Markll Programming
If SMDR output of incoming calls is required, Memory Block 2A6, Line Key 1 must be ON.
In memory Block 2D1, Line Key 4 represents the time until the Electra Markll will begin recording the duration
of the call.
In memory Block 2D1, Line Key 13 represents the time that must pass on a call before the Electra Markll will
provide an SMDR report.
Memory Block 2A8 allows you to program the number of digits that will be used for Account Codes.
Scout Jr. Programming
The following is general information concerning the programming required with Scout Jr. for a customer’s
site:
l
Site Information:
Company Name
Company Address
Company Telephone Number
l
Department Numbers
l
Extension Numbers and Names of Users
l
Trunks: (Types of Trunks Used and Numbers)
l
Call Pricing Information: Carrier (MCI, Sprint, AT&T, etc.)
The call pricing can also be customized for a customer’s needs.
(Refer to the Scout Jr. manual for additional information.)
2OF3