4.5From one end of the station cable provided (step 3.4) remove approximately 4 inches of outer insulation

and strip off $ inch of the inner insulation from each of the four wires. To each conductor fasten one of

the spade lugs locally provided, either by soldering or crimping.

4.6To remove the access panel, perform only the step that applies, either 4.6.1 or 4.6.2 (Refer to Figure 1).

4.6.1ETE-GD-1, ETE-IGD-1, or ETE-16K-1 Multiline Terminal; Insert a flat scrcwdriver.bladc into

notched opening (shown as A) and apply light upward pressure until the access panel clears the

front lip, at the same time apply pressure (toward you) at the rear of the pedestal (shown as I~) until the access panel moves toward you. Remove panel.

4.6.2ETE-6-1 Multiline Terminal; Depress the flexible notched tab (shown as C) on the access panel

and apply upward pressure. Remove panel.

NOTE:

Do not discard removed access panel: sate forpossible future use.

4.7Locate the four pin connector and jack labeled HAND (as seen through the access view of the Multiline

Terminal housing). Unplug this connector and extend it out from the housing access opening.

4.8Set the SW2 Dip switches, on the ADA-E unit, as shown in Table 1 of Figure 2. Place the jumper across pin ST2 and the center pin. Set SW1 to the BREAK position.

4.9Make the wiring connections as indicated in Figure 2. The connections between Tl & T5 and bctwccn T2 & T4 are made with the jumper wires provided in the ADA-E kit. If necessary, USCa section of the

clear plastic tubing provided in the ADA-E kit to insulate the connections.

4.10Locate and insert the four pin connector ended harness from the ADA-E unit into the jack labeled

HAND on the Multiline Terminal.

4.11Locate and insert the eight pin connector ended harness from the ADA-E unit into the jack labeled

ADA on the Multiline Terminal.

4.12Insert the four pin connector ended harness (removed in step 4.7) into the four pin jack, CN3, located on the ADA-E unit.

4.13Install the ADA-E unit with the component side down ensuring the wires are not pinched. Sccurc the

ADA-E unit to the terminal housing with the screw provided as shown in Figure 3.

NOTE: Two access panels are provided with the ADA-E kit; a narrow panel to be used with E’l’E6-I

Multiline

Terminals

and a wide panel to be used with all other terminals.

Knsure the correct access p;tnc!l is

used.

 

 

 

4.14Route the locally provided station wire (already connected to the ADA-E unit) through one of the two notched grooves on the access panel. Install the access panel.

4.15Install the RJ-35X block in a convenient location. Connect the station cable from the ADA-E unit to

the RJ-35X block, connecting Red to Red, Green to Green, etc.

4.16Plug the modular cord from the Autodialer into the M-35Xreceptacle.

4.17Slide the directory back into place, if required.

2of6

Page 631
Image 631
NEC nd-20292 manual Knsure the correct access ptnc!l is