ND-20292
CHAPTER 3
APRIL, 1990
MEMORY BLOCK 4E6 - TLI - III INITIALIZED VALUES
OPERATION
-AND-
DISPLAY
1. Go off line.
2. Depress F4, then FlO.
3. Depress F16.
4. Dial the number of the Trunk Group (1 - 8) to be
assigned. Example: Trunk Group 4. (See Note 1.)
5. Depress Ll - L8 and L13 - L16 to set the required
timing parameters to the selected Trunk Group.
(See Note 2.)
6. Depress ENTER key. (See Note 7.)
OF F - LINE (X-XX)
PROGRAM MODE
TLI PROGRAMMING
TLl I NI TI ALI ZE3
TRUNK GROUP?
TLl I NI TI ALI ZE3
TRUNK GROUP4
.: -3,
:
TLl INITIALIZE3 .>
TRUNK GROUP4
-T L I I NI TI ALI ZE3
TRUNK GROUP?
7. Repeat steps 4 thru 7 for all Trunk Groups, associated with TLI-E( ) ETUs, to be programmed.
8. Depress the SPKR key to go back on line.
300 - 228