ETI NUMBER: MK-018

4.PROCEDURE

4.1Scout Jr. Installation

Load the call accounting software into the computer in accordance with the Scout Jr. manual. Scout Jr. already contains the switch parameters for the Electra Markll; therefore, choose the item number that represents the Electra Markll in the switch setup during installation.

4.2Connections (refer to Figure 1)

4.2.1install the SMDR-E ETU into an available option slot in a CCU. (Refer to Chapter 2 of the Installation Service

Manual.)

..

 

4.2.2Connect one end of the RS-232C cable to the female connector of the SMDR-E ETU. Connect the other end of the RS-232C cable to a COM Port on the computer.

4.3Electra Markll Programming

4.3.1If SMDR output of incoming calls is required, Memory Block 2A6, Line Key 1 must be ON.

4.3.2In memory Block 2D1, Line Key 4 represents the time until the Electra Markll will begin recording the duration of the call.

4.3.3In memory Block 2D1, Line Key 13 represents the time that must pass on a call before the Electra Markll will provide an SMDR report.

4.3.4Memory Block 2AB allows you to program the number of digits that will be used for Account Codes.

4.4Scout Jr. Programming

The following is general information concerning the programming required with Scout Jr. for a customer’s site:

l

l l l l

Site Information: Company Name Company Address Company Telephone Number

Department Numbers

Extension Numbers and Names of Users Trunks: (Types of Trunks Used and Numbers)

Call Pricing Information: Carrier (MCI, Sprint, AT&T, etc.)

The call pricing can also be customized for a customer’s needs.

(Refer to the Scout Jr. manual for additional information.)

2OF3

Page 704
Image 704
NEC nd-20292 manual ETI Number MK-018