ETI NUMBER: MK-012A

6.4 Electra Markll System programming (Refer to the Electra Markll Installation Service Manual)

:’

6.4.1Assign individual trunks for OIT or ANA operation in Memory Blocks 283 and 284. (Delay Announcement is available for OIT or ANA trunks only).

6.4.2Assign the Delay Announcement feature to each required OIT or ANA trunk in Memory Block 2C5.

6.4.3Assign desired time delay between incoming ring signal recognition and the start of the Delay Announcement to the calling party in Memory Block 202, using line key 6. This timer is adjustable from 1 to 99 seconds. System default value is 20 seconds.

6.4.4Assign the desired defay Announcement Auto Release Timer in Memory Block 201, using line key 3. This timer determines how long an outside line will remain connected to the announcement device after encountering either a busy signal or no answer from a Hunt Group. If the outside line can provide a remote disconnect signal this timer is not required, the remote disconnect will supersede this timer. Timer ranges from 10 to 980 seconds with 990 being infinity, and can be disabled. Default value is 600 seconds (10 minutes).

6.4.5Select one of the ECR-E ETU relays to activate the announcement of relay number 10 is recommended for the first announcement. for the second delay announcement. (See Figure 1).

unit in Memory Block 2C9. Use Relay number 9 is recommended

6.4.6Assign the duration for the first and second delay announcements in memory block 202. Line Key 7 represents the first announcement and Line Key 8 represents the second announcement. Timer ranges are from l-98 seconds with 99 being infinity. Default is 10 seconds (Series 400 only).

NOTE:

If the timer assignment is between l-98 seconds, MOH will automatically begin after the assigned, time. If

 

timer assignment is 99, the announcement will continue to replay (same as Series 300).

6.4.7Assign the MOH duration between the first and second announcements (LKZ) and between the second and repeat of the second announcement (LK8) in memory block 201. timer ranges are from lo-980 seconds with 99 being infinity (Series 400 only).

NOTE:

If the time

assignment between

the

1stand 2nd announcement is lo-980 seconds, JK3 (2nd Announcement

 

input) will

automatically be the

input for the Second Delay Announcement and the TSW-E/EB MOH

inputs

 

become the input for Station BGM.

If the timer is left at default, 99 (infinity), JK3 is the input for

Station

 

BGM.

 

 

 

 

6.4.8If station Hunt Groups are required, use Memory Blocks 3B5 through 3B8 to assign the required parameters.

7.AllENOANTACTlVATlON AN0 DEACTIVATION OF DELAY ANNOUNCEMENT

7.1 To Activate Day/Night Time Delay Announcement: (Idle mode)

7.1.1Depress the CNF key.

7.1.2For Day Time Delay Announcement, depress line key 9 (LED turns ON)

7.1.3For Night Time Delay Announcement, depress line key 10 (LEO turns ON)

7.1.4Depress the CNF key to return ON LINE.

7.2For deactivating Day time and Night time Delay Announcement, repeat the same procedure for activating the announcement, except turn the LEOsOFF instead of ON.

4OF7

Page 801
Image 801
NEC nd-20292 manual Bgm