ET1 NUMBER: DT-002

DATE: DECEMBER 1988

5.12Locate and insert the eight pin connector ended harness from CNl and CN2 on the ADA-E unit into the jack labeled “ADA” in the Multiline Terminal.

5.13Insert the four pin connector ended harness (removed in step 5.7) into the four pin jack, CN3, located on the ADA-E unit.

5.14Install the ADA-E unit and secure it to the terminal housing with the screw provided, as shown in Figure 2.

5.15Two access panels are provided with the ADA kit, the narrower panel is used with the ETE-6-2 and ETE- 16-2 Multiline Terminals, the wider panel for all other Terminals. Remove the plastic tongue on the underside of the access panel being installed (using a pair of pliers) to provide clearance for cables in the cable exit groove.

5.16Place the RJ-35X cable into the cable exit groove (Figure 2) making certain that all wires are inside the terminal housing. Install the proper access panel.

5.17Reinstall the modular handset and modular line cords.

5.18If slid out of the way in step 5.4, slide the directory back into place.

5.19Plug the modular line cord of the Autodialer into the RJ-35X receptacle.

5.20Plug in the Autodialer AC Adapter, first into the Autodialer and then into the nearest AC outlet.

5.21Test both the Autodialer and the Multiline Terminal for proper operation.

3 of 6

Page 752
Image 752
NEC nd-20292 manual ET1 Number DT-002 Date December