ETI NUMBER: DS-003

Table - 1 Jackset 15-180 Cable Connection (ETE-1-2 Rev. A)
JACKSET JS-180 CABLE Dterm II PCB SPADE LUG
CONNECTORS
VIOLET H3
RED Hl
ORANGENVHIT TX1
YELLOW/WHITE TX2
YELLOW RX
BLACK** RX1
ORANGE RX2
BLUE Jl
BROWN 13
**NOTE: For better voice quality, connect a 3.6K ohm resistor between the
Black wire and Spade lug RX1
I
+ Dterm II PC8
BLUE
I
11
cl
Hook Switch
lb4lbJ4B4l
e
/
RED
YELLOWNYHITE
3.6Kn
YELLOW
1
ORANGE I
BLACK
Figure 2. Jackset JS- 180 wire Connection On Dterm I I (ETE- l-2) PCB (Rev. A)
BROWN
ORANGEIWHITE
SPARE
WIRES,
TAPE
-0
INSULATE
To JS-180
NOTE: If the Jackset 15-180 is disconnected from the ETE-l-2 telephone, Strap 58 must be reconnected for proper
operation of the telephone.
3OF5