ET1 NUMBER: MK-012

DATE: DECEMBER 1988

6.3.5Connect the 12-14V power pack into the AEC 212 first, and then into the nearest AC power outlet.

6.3.6Using the built-in microphone, or a carbon type handset, record the desired announcement as indicated in the AEC 212 Plus owner’s manual. For maximum effectiveness, it is recommended that the message be limited to a maximum of 15 seconds followed by a silent period of 2 seconds.

6.4Electra MarkII system programming (Refer to the Electra Mark11 Installation Manual)

6.4.1Assign individual trunks for DIT or ANA o eration in Memory Blocks 2B3 and 2B4. (Delay Announcement is availab l!e for DIT or ANA trunks only).

6.4.2Assign the Delay Announcement feature to each required DIT or ANA trunk in Memory Block 2C5.

6.4.3Assign desired time delay between incoming ring signal recognition and the start of the Delay Announcement to the calling party in Memory Block 2D2, using line key 6. This timer is adjustable from 1 to 99 seconds. Use of the system default value (20 seconds) is recommended.

6.4.4Assign the desired Delay Announcement Auto Release Timer in Memory Block 2D1, using line key 3. This timer determines how long an outside line will remain connected to the announcement device after encountering either a busy signal or no answer from a Hunt Group. If the outside line can provide a remote disconnect signal, the remote disconnect will supercede this timer if the remote disconnect signal occurs before the timer elapses. Timer ranges from 10 to 990 seconds and can be disabled. Default value of 600 seconds (10 minutes) is recommended.

6.4.5Select one of the ECR-E ETU relays to activate the announcement unit in Memory Block 2C9. Use of relay number 10 is recommended. (See Figure 1)

6.4.6If station Hunt Groups are required, use Memory Blocks 3B5 thru 3B8 to assign the required parameters.

6.4.7Activate the Day and Night Delay Announcement feature from an idle Attendant station as follows:

6.4.7.1Depress CNF key.

6.4.7.2Depress line key 9 (for Day Mode) and 10 (for Night Mode) (Both LEDs illuminate).

6.4.7.3Depress CNF key (to return ON LINE).

7.TESTING

After installation and programming is completed, test the operation as follows: