DIP 1

m48x100

m24

11111 12

I6

I3

El

ON OFF

Figure ZOO-25 SMDR-E DIP1 Switch

LED1 (Green) lit, indicates that the SMDR-E ETU is receiving power.

2.Connection of SMDR

A.The SMDR-E ETU must be installed into either OPT1 or OPT2 slot (or a combination

slot) of any CCU. Prior to installing the SMDR-E ETU, ensure that switch SW1 is set to the ON position and that the baud rate switch, DIPl, is set to the proper position.

When installing the SMDR-E ETU, turn SW2 OFF for insertion of this ETU into the slot without powering down the CCU.

B.Route the RS-232C connector ended cable down and to the right side of the CCU in a

manner to avoid interference with the insertion and the removal of ETUs and with

the 25pair cables from Jl - 53 connectors. Remove the access panel on the right side of the CCU, which covers three openings, to

mount RS-232C connectors. (See Figure

200-26).

0

0

0

ND-20292

CHAPTER 2

APRIL, 1990

Mount the RS232C connector in one of the openings using screws and nuts locally provided. (See Figure 200-27.)

C.Connect a printer or other peripheral device to the RS232C connector mounted on the CCU in Step B. Secure the RS-232C male

connector from the printer or other peripheral device with the screws provided with the device.

D.Turn ON SW2 of the SMDR-E ETU.

3.A 25 pin RS-232C connector is provided with the

following pin configuration. (All pins are active high).

SMDR-E ETU Output Connector

PIN # FUNCTION

2TXD (Transmit Data)

3RXD (Receive Data)

4RTS (Request To Send)

5 CTS (Clear To Send)

6DSR (Data Set Ready)

7 Signal Ground

8DCD (Data Carrier Detect) (constant high)

20DTR (Data Terminal Ready)

SMDR printout string is as follows:

0 ASCII

l7 bits even parity

0 One stop-bit.

4.SMDR Output Format:

For SMDR general format and sample printouts of call record, refer to Figures 200-28 and 200-29.

\LOOSEN SCREW AND REMOVE ACCESS PANEL

Figure 200-26 Right Side View of CCU

240.8LCR-EETU

The LCR-E ETU contains three switches, an LED and a RS-232C connector ended cable.

1.Switches:

Switch 1, designated SWL, is used to connect

backup battery to the LCR-E MEMORY. This switch should be set to the ON position to allow

memory retention during power failure or brownouts, for approximately seven days.

Switch 2, designated SW2 RESET, is a slide switch used to reset the LCR-E ETU, with interruption of all ongoing operation. This switch is also used to busy out the ETU when the ETU is

200-29

Page 61
Image 61
NEC nd-20292 manual 200-26, Lcr-Eetu, 200-29, PIN # Function, Ascii