1. DESCRIPTION

This Engineering Technical Information (ET11 Bulletin describes the steps necessary to install an ADA-E (Ancillary Device Adapter) unit into an ETE-6D-2, ETE-16D-2, ETE-16-2, or ETE-6-2 Multiline Terminal, to provide for connectio and operation of a Plantronics Jackset (Model JS-180).

2:PARTS REQUIRED

2.1ADA-E Unit Adapter Kit (Stock # 5602801

2.2JS-180 Jackset

2.3Compatible Headset

2.4Dterm Series II Multiline Terminal

3.OPERATION

3.1By moving the Jackset “Rocker Switch” to the ON position, the Dterm Series [I Multiline Terminal will go into tk OFF-HOOK condition. The operator can now talk over the headset, after depressing a CO or extension line key o the Multiline Terminal.

3.2The call can be terminated by moving the “Rocker Switch” to the OFF position.

3.3The LMultiline Terminal is seen as OFF-HOOK when the Jackset is turned on, therefore, it may be desirable to program the Multiline Terminal for off-hook ringing.

4.PROCEDURE

4.1Turn the Multiline Terminal upside down (face down) and locate the access panel on the bottom of the Multiline Terminal, refer to Figure 1.

4.2Disconnect the modular line cord from under the telephone and from the RJ-llC/W jack.