ET1 NUMBER: DT-002

DATE: DECEMBER 1988

4.OPERATION

4.1Access an idle CO/PBX line.

4.2On the Autodialer, depress the ON/OFF button; then depress the desired Speed Dial button.

4.3Monitor the call through the speaker of the Autodialer.

4.4When called party answers, lift the handset and converse.

4.5After call is established, manually turn OFF the Autodialer by depressing it’s ON/OFF button.

5.PROCEDURE

5.1Turn the Multiline Terminal upside down (face down) and locate the access panel on the bottom of the Multiline Terminal, refer to Figure 1.

5.2Disconnect the modular line cord from under the telephone and from the ELJ-llC!/W jack.

5.3Disconnect the modular handset cord from the lower housing.

5.4Slide the directory out of the way (Not required for ETE-6-2 or ETE-16-2 Multiline Terminal).

5.5Removal of access panel (Perform only the step that applies, either 5.5.1 or 55.2) Refer to Figure 1.

5.5.1ETE-6D-2 or ETE-16D-2 Multiline Terminal; Insert flat screwdriver blade into notched opening shown as

A)and apply light upward pressure until access panel is cleared of the front lip, at the same time apply pressure (towards you) at the rear of the pedestal (shown as B) until the access panel moves towards you. Remove panel.

5.5.2ETE-6-2 or ETE-16-2 Multiline Terminal, depress spring loaded notched tab (shown as C) on the access panel and apply upward pressure. Remove panel.

NOTE:

Do not discard removed access panel. While it will not be used at this time, save for possible future

5.6Locate the eight pin jack labeled “ADA”, as seen through the housing access opening of the Multiline Terminal housing.

5.7Unplug the four pin connector ended harness (labeled “HAND”) and extend it out from the housing access opening, of the Multiline Terminal.

5.8Set the Dip switches on the ADA-E unit as shown on Table 1 (See Figure 3). Place the jumper strap across ST2 and the center pin. Set SW1 to the “BREAK” position.

5.9Remove approximately 3 inches of outer insulation from both ends of the 4 conductor station wire cable and strip off + inch of wire insulation from each of the four wires; solder or crimp a spade lug to each wire end.

5.10Make the RJ-35X connections as indicated in Figure 3 using the prepared 4 conductor station wire cable. Use one of the two spade tipped jumper wires provided with the ADA kit to make a connection between Tl and T5; connect the other jumper wire between T2 and T4 on the ADA-E unit.

5.11Locate and insert the four pin connector ended harness from CNl on the ADA-E unit into the jack labeled “HAND” in the Multiline Terminal.