Patton electronic SmartNode 4110 Series Nodectx-csswitch#show call-router config detail, Level

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 350
Image 350

SmartWare Software Configuration Guide

31 • CS context overview

 

 

Mode: Context CS

Step

Command

Purpose

 

 

 

 

1

node(ctx-cs)[switch]#show call-router config detail

Show the CS context configuration.

 

level

Level could be 1..5. Level 1 shows less,

 

 

level 5 shows all information.

 

 

 

2

node (ctx-cs)[switch]#debug call-router detail level

Enable the call-router debug monitor.

 

 

Level could be 1..5. Level 1 only logs

 

 

errors, level 5 shows all relevant infor-

 

 

mation to track calls through routing

 

 

tables.

 

 

 

3

node (ctx-cs)[switch]#no shutdown

Enable the CS context, checks the inter-

 

 

face and call router configuration

 

 

 

4

node(ctx-cs)[switch]#show call-router status detail

Show the actual state of the call router.

 

level

This includes all configured tables as

 

 

they were read-in from the configura-

 

 

tion.

 

 

 

Example: Enable CS Context

The following example shows how to enable the call router debug monitor and how to enable the CS context. It also shows the output from the call router debug monitor.

node(cfg)#show call-router config detail 5

 

 

Table switch/TAB-ISDN-SERVICE:

 

 

 

Key

Value

Function

Dest-Type

Dest-Name

itc

-

 

 

 

-------------------------------------------------------------------------------

unrestricted-digital -

-

dest-interface

IF-LOCAL-BA

default

-

-

dest-table

TAB-DEST-A

Table switch/TAB-DEST-A:

 

 

 

Key

Value

Function

Dest-Type

Dest-Name

called-e164

-

 

 

 

-------------------------------------------------------------------------------

0

-

MAP-CAC-ORANGE

dest-interface

IF-LOCAL-BA

00

-

MAP-CLI-MELON

dest-interface

IF-NODE-C

07[4-6]

-

MAP-CAC-APPLE

dest-interface

IF-LOCAL-BA

0336652...

-

-

dest-interface

IF-NODE-B

default

-

-

dest-interface IF-LOCAL-BA

Table switch/CAC-APPLE:

 

 

 

Key

Value

Function

Dest-Type

Dest-Name

called-e164

called-e164

 

 

 

-------------------------------------------------------------------------------

(.%)

1055\1

-

-

-

...

 

 

 

 

node(cfg)#debug call-router node(cfg)#context cs node(ctx-cs)[switch]#no shutdown

Activating CS context configuration

350

Page 350
Image 350
Patton electronic SmartNode 4110 Series manual Nodectx-csswitch#show call-router config detail, Level