SmartWare Software Configuration Guide

40 • Call router configuration

 

 

The possible values for the type argument are:

transparent: Transparently passes an address-complete indication (e.g. ISDN Sending Complete Informa- tion Element) to the call-control.

set: Always sets the address-complete indication flag towards the call-control even when no such indication is received from the calling party. This configuration can be used to disable overlap-sending on an interface.

clear: Never signals the address-complete indication towards the call-control even when the indication is received from the calling party. This configuration may be used in rare cases to solve interoperability prob- lems with attached PBXs.

Some interface types do not support all of the mentioned arguments. The following table shows the supported address-complete indication conversion types and the default setting for each interface type:

Interface Type

Transparent

Set

Clear

 

 

 

 

ISDN

supported; default

supported

Supported

 

 

 

 

H.323

supported; default

supported

Supported

 

 

 

 

SIP

not supported

supported

supported; default

 

 

 

 

Call-Router

The call-router is extended to be able to set the address-complete indication or append a terminating-character in some circumstances. This includes:

Setting the address-complete indication when the digit-collection timeout elapses

Appending the terminating-character when the digit-collection timeout elapses

Filtering-out the terminating-character and optionally set the address-complete indication

Setting the address-complete indication when a called-party number matches a fully specified call-router rule ($-terminated entry).

Appending the terminating-character when the called-party number matches a fully specified call-router rule ($-terminated entry).

The command digit-collection timeout <secs> has been extended with two optional arguments that specify whether a terminating-character is appended or the address-complete indication set when the digit-timeout elapses. The command syntax is

[no] digit-collection timeout <secs> [append-terminating-char] [set-address-complete-indication]

The extensions configure the action(s) to be performed when the digit-collection timeout elapses. The digit- collection timeout runs when a call is routed to a called-e164 routing-table of which a T-terminated rule is selected. Two actions are available; both can be enabled independently. The append-terminating-charaction appends the configured terminating-character when the timeout elapses. The set-address-complete-indicationaction sets the address-complete indication. Whether or not the egress interface propagates the address-com- plete indication depends on the interface configuration (see below).

Call router configuration task list