SmartWare Software Configuration Guide

36 • FXO interface configuration

 

 

Configuring how to detect a call has disconnected (optional)

When a call has disconnected, the FXO interface may detect and verify the termination of the phone call by three different methods.

Detect a busy tone or release tone

Detect a loop break (if provided by the FXS switch)

Detect battery reversal (if provided by the FXS switch)

Detect a dtmf signal

Configure loop break timing

The selection of the method, if any of the three, is via the disconnect-signalcommand. The default enables only loop-break. Upon detecting a loop break, the FXO interface proceeds to clear the call on the SmartNode. In some instances, the user may need to transmit all of the in-band information (tone signal, announcement) to the end party after disconnection has occurred.

The disconnect-signalcommand can be used to enable or disable the three detection methods. If all three methods are disabled, the call is cleared after a period of 30 seconds from reception of the disconnect signal. Consequently it becomes the responsibility of the end party to execute the on-hook (completing the discon- nection phase) for the call to be completely cleared.

Note Verify that the busy and release tones are correctly configured for the country where the SmartNode is installed (see chapter 42, “Tone configuration” on page 529 for configuration information. If the tones are improperly config- ured, the FXO port will not detect them, resulting in missed phone calls.

Mode: Interface FXO

Step

Prompt, command & response

Purpose

 

 

 

1

node(if-fxo)[if-name]#[no] disconnect-signal

The default is Loop-break. To disable it, use

 

{battery-reversal busy-tone loop-break}

the no inverse command. Should all three

 

 

methods be disabled, the call is cleared 30

 

 

seconds after receiving the disconnect signal.

 

 

The default setting of loop-break is not dis-

 

 

played in the running-config output.

 

 

 

2

[name] (if-fxo) [interface]# [no] disconnect-sig-

Disconnects the call upon reception of one of

 

nal dtmf <dtmf-digits>

the specified DTMF digits.

3[name] (if-fxo)[interface]#loop-break-durationSpecifies the timing of the loop break signal.

[min <min-time>] [max <max-time>]

Shorter breaks are ignored, longer breaks

 

are treated as line down.

 

Min specifies the minimum time of a valid

 

loop break (Default 60ms). Max specifies the

 

maximum time of a valid loop break (Default

 

600ms). Please note that the internal timer

 

has a resolution of 40ms.