SmartWare Software Configuration Guide

26 • SNTP client configuration

 

 

Enabling and disabling the SNTP client

The SNTP client is disabled by default and has to be enabled if clock synchronization shall be used. This pro- cedure describes how to enable or disable the SNTP client

Mode: Configure

Step

Command

Purpose

1node(cfg)#[no] sntp-clientEnables the SNTP client operation. Using the no command syntax dis- ables this feature.

Example: Enabling the SNTP client operation

node(cfg)#sntp-client

Example: Disabling the SNTP client operation

node(cfg)#no sntp-client

Defining SNTP client poll interval

Specifies the seconds between each SNTP client request in unicast or anycast mode.

This SNTP client poll interval can be defined to be within the range from 1 to 4’294’967’295. The default value is 60 seconds.

This procedure describes how to set the SNTP client poll interval

Mode: Configure

Step

Command

Purpose

1node(cfg)#sntp-clientpoll-intervalvalue Sets the SNTP client poll interval to value seconds

Example: Setting the SNTP client poll interval

In the following example the SNTP client poll interval is set to 30 seconds.

node(cfg)#sntp-client poll-interval 30

SNTP client configuration task list