Patton electronic SmartNode 4110 Series manual Dial-up on monitor, Dial-up nailed

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 338
Image 338

SmartWare Software Configuration Guide

30 • PPP configuration

 

 

Dial-up on monitor

Dial when a monitored interface is reported down and drop when that interface is reported up again. A delay time prevents to dial or drop if the monitored interface changes the state only for a short time.

Mode: context ip/interface

Step

Command

Purpose

 

 

 

1

[name] (if-ip) [interface]#[no] dial-up mon-

Configure dial-up to monitor the interface

 

itor interface <ip-interface> [dial delay

specified. Dial delay specifies the timeout

 

<seconds>] [drop delay <seconds>]

before dialing (Default 10). Drop delay speci-

 

[queue-limit <number>]

fies the timeout before dropping connection

 

 

(Default 10). Queue-limit specifies the max.

 

 

number of packets to queue while the link is

 

 

down (Default 4).

 

 

 

Dial-up nailed

Dial if possible, and never drop.

Mode: context ip/interface

Step

Command

Purpose

 

 

 

1

[name] (if-ip) [interface]#[no] dial-up

Configure dial-up nailed. Queue-limit speci-

 

nailed [queue-limit <number>]

fies the max. number of packets to queue

 

 

while the link is down (Default 4).

 

 

 

PPP Dial-up over ISDN