SmartWare Software Configuration Guide

40 • Call router configuration

 

 

Table 21. Hunt group drop causes (Continued)

 

 

Default Behavior

 

Class

Cause

of the Hunt

Description

 

 

Group Service

 

 

 

 

 

Protocol Error

ie-does-not-exist

Drop original call

The remote equipment receives a message

(Cont.)

 

 

that includes information elements or call

 

 

 

properties that are not recognized.

 

 

 

 

 

invalid-ie-contents

Drop original call

The remote equipment receives a message

 

 

 

that includes invalid information in the

 

 

 

information element or call property.

 

 

 

 

 

recovery-on-timer-

Drop original call

Your call was not completed, probably

 

expiry

 

because an error occurred.

 

 

 

 

 

 

 

 

protocol-error

Drop original call

An unspecified protocol error with no

 

 

 

other standard cause occurred.

 

 

 

 

Interworking

interworking

Drop original call

An event occurs, but the network does not

 

 

 

provide causes for the action it takes. The

 

 

 

precise problem is unknown.

 

 

 

 

Example: Create a hunt group service

This example shows how to configure the hunt group service as shown in figure 66 on page 498.

node(cfg)#context cs node(ctx-cs)[switch]#service hunt-group HUNT-BRI node(func)[HUNT-BRI]#cyclic node(func)[HUNT-BRI]#timeout 6 node(func)[HUNT-BRI]#route dest-interface IF-BRI0 node(func)[HUNT-BRI]#route dest-interface IF-BRI1 node(func)[HUNT-BRI]#route dest-interface IF-BRI2 node(func)[HUNT-BRI]#route dest-interface IF-BRI3