SmartWare Software Configuration Guide

15 • Frame Relay configuration

 

 

Example: Entering Frame Relay PVC configuration mode

The following example enters the configuration mode for PVC with the assigned DLCI of 1 for Frame Relay over the serial interface on slot 0 and port 0.

node(cfg)#port serial 0 0 node(prt-ser)[0/0]#framerelay node(frm-rel)[0/0]#pvc 1 node(pvc)[1]#

Configuring the PVC encapsulation type

You must use the PVC configuration command encapsulation rfc1490 to set the encapsulation type to com- ply with the Internet Engineering Task Force (IETF) standard (RFC 1490). Use this keyword when connecting to another vendor’s equipment across a Frame Relay network.

This procedure describes how to set the encapsulation type to comply with RFC 1490

Mode: Frame Relay/PVC

Step

Command

Purpose

 

 

 

1

node(pvc)[dlci]#encapsulation rfc1490

Sets RFC1490 PVC compliant encapsulation

 

 

 

Example: Configuring the PVC encapsulation type

The following example sets the encapsulation type to comply with RFC 1490 for PVC with the assigned DLCI of 1 for Frame Relay over the serial interface on slot 0 and port 0.

node(cfg)#port serial 0 0 node(prt-ser)[0/0]#framerelay node(frm-rel)[0/0]#pvc 1 node(pvc)[1]#encapsulation rfc1490

Binding the Frame Relay PVC to IP interface

A newly created permanent virtual circuit (PVC) for Frame Relay has to be bound to an IP interface for further use. The logical IP interface has to be already defined and should be named according to the use of the serial

Frame Relay configuration task list

182

Page 182
Image 182