SmartWare Software Configuration Guide

34 • ISDN interface configuration

 

 

Configuring Call-Hold on ISDN interfaces

Normally, the call-hold feature is disabled on ISDN point-to-point links and enabled on ISDN point-to-mul- tipoint links. However, you can manually enable or disable the Call-Hold feature using the following com- mand: The default setting can be achieved using the ‘auto’ configuration option.

Mode: interface isdn

Step

Command

Purpose

 

 

 

1

node(if-isdn)[if-name]# call-hold

Enable or disable the call-hold functionality for

 

{autoenabledisable}

an isdn interface. If ‘auto’ is selected, call-hold is

 

 

automatically disabled on p2p links and enabled

 

 

on p2mp links.

 

 

Default: auto

 

 

 

Enabling Display Information Elements on ISDN Ports

By default no display information elements are sent in ISDN signaling messages. You can enable sending of ISDN Display Information elements in ISDN signaling messages using the following command.

Mode: interface isdn

Step

Command

Purpose

 

 

 

1

node(if-isdn)[if-name]# [no] display

Enable sending of the display information ele-

 

emit

ment for an isdn interface.

 

 

Default: disabled

 

 

 

Configuring date/time publishing to terminals (optional)

ISDN allows to propagate current time and date information from a port configured as network to the con- nected terminals. You can configure each ISDN interface to propagate the current SmartNode system time and date to the connected terminals with the following command:

Procedure: To configure date and time publishing

Mode: Interface ISDN

Step

Command

Purpose

1node(if-isdn)[if-name]#[no] isdn-date-time

Enable/disable publishing of system time to con- nected ISDN terminals (default: disabled)

Date and time information can only be contained in the ISDN CONNECT message. This message is only delivered to a terminal when a call from the terminal to the SmartNode is made, and reaches connected state.

ISDN interface configuration task list

394

Page 394
Image 394
Patton electronic SmartNode 4110 Series manual Configuring Call-Hold on Isdn interfaces