SmartWare Software Configuration Guide

14 • Serial port configuration

 

 

Example: Disabling an interface

The example shows how to disable the built-in serial interface on slot 0 and port 0 of a SmartNode. Check that State is set to CLOSED in the command output of show port serial.

node(cfg)#port serial 0 0 node(prt-ser)[0/0]#shutdown node(prt-ser)[0/0]#show port serial

Serial Interface Configuration

------------------------------

Port

:

serial 0 0 0

State

:

CLOSED

Hardware Port

:

V.35

Transmit Edge

:

normal

Port Type

:

DTE

CRC Type

:

CRC-16

Max Frame Length:

2048

Recv Threshold

:

1

Encapsulation

:

 

Enabling an interface

After configuring the serial interface or connecting other serial devices, use the no shutdown command to enable the serial interfaces again. When you enable an interface, it has the state OPENED in the show port serial command display.

Note Use the shutdown command to disable the serial interface for any software or hardware configuration procedure.

This procedure describes how to enable a serial interface.

Mode: Administrator execution

Step

Command

Purpose

 

 

 

1

node(cfg)#port serial slot port

Selects the serial interface on slot and port

 

 

 

2

node(prt-ser)[slot/port]#no shutdown

Enables the interface

 

 

 

3

node(prt-ser)[slot/port]#show port serial

Displays the serial interface configuration.

 

 

 

Example: Enabling an interface

The example shows how to enable the built-in serial interface on slot 0 and port 0. Check that State is set to OPENED in the command output of show port serial.

node(cfg)#port serial 0 0 node(prt-ser)[0/0]#no shutdown node(prt-ser)[0/0]#show port serial

Serial Interface Configuration

------------------------------

Port

:

serial

0 0 0

State

:

OPENED

 

Serial port configuration task list

172

Page 172
Image 172
Patton electronic SmartNode 4110 Series manual Enabling an interface