SmartWare Software Configuration Guide16 • PRI port configuration

Mode: Operator execution

 

Step

Command

Purpose

 

 

 

 

1

[name]#[no] debug hw-type

Enables/Disables the PRI event/error monitor for the

 

 

[ ( [<slot> [<port>] ] ) [ [event]

device a slot or a port.

 

 

[error] ] ]

Examples:

 

 

 

 

 

 

1)[no] debug e1t1

 

 

 

Enables/Disables the event and the error monitor for

 

 

 

all e1t1 ports of the device.

 

 

 

2)[no] debug e1 event

 

 

 

Enables/Disables the event monitor for all e1 ports

 

 

 

of the device.

 

 

 

3)[no] debug t1 error

 

 

 

Enables/Disables the error monitor for all t1 ports of

 

 

 

the device.

 

 

 

4)[no] debug e1 3

 

 

 

Enables/Disables the event and error monitor for all

 

 

 

e1 ports on slot 3.

 

 

 

5)[no] debug e1t1 1 event

 

 

 

Enables/Disables the event monitor for all e1t1

 

 

 

ports on slot 1.

 

 

 

6)[no] debug t1 2 error

 

 

 

Enables/Disables the error monitor for all t1 ports

 

 

 

on slot 2.

 

 

 

7)[no] debug t1 0 0

 

 

 

Enables/Disables the event and error monitor for the

 

 

 

t1 port 0 on slot 0.

 

 

 

8)[no] debug e1 1 0 event

 

 

 

Enables/Disables the event monitor for the e1 port 0

 

 

 

on slot 1.

 

 

 

9)[no] debug e1t1 2 0 error

 

 

 

Enables/Disables the error monitor for the e1t1 port

 

 

 

0 on slot 2.

 

 

 

 

Mode: Operator execution

 

 

 

 

 

 

Step

Command

Purpose

 

 

 

 

1

[name]#show port hw-type

Prints information about the specified port with a

 

 

[ [<slot> <port>] [detail <level>] ]

given detail level.

 

 

 

 

PRI Configuration Examples

Here is a group of seven configuration examples.

Example 1: ISDN

Example 2: RBS without a channel-group

Example 3: RBS with a channel-group

PRI port configuration task list