SmartWare Software Configuration Guide

36 • FXO interface configuration

 

 

Note Verify that you have configured the dial-tone for the country in which the SmartNode is installed. (see chapter 42, “Tone configuration” on page 529). If the dial-tone is not configured for the proper country, the FXO interface will not detect when the remote FXS switch is sending dial-tone.

Configuring the number of rings to wait before answering the call (optional) An FXO port identifies an incoming call by detecting the ring from the FXS switch. The ring-numberis a configurable parameter which selects the number of rings before answering the incoming call, that is, before going off-hook and establishing the call. The minimum value for ring-numberis zero (0). With a ring-num- ber of zero, the FXO interface never answers an incoming call.

Due to variations between countries, the proper setting may be 1 or 2. In the USA the Caller-ID (CLID) is sent to the FXO port between the first and second ring, so a ring-number of 2 would be appropriate. On the other hand, numerous countries send the CLID prior to the first ring, so the default setting of 1 would be satisfactory.

Mode: Interface FXO

Step

Prompt, command & response

Purpose

 

 

 

1

node>

Basic prompt in Operator Exec mode

 

 

 

2

node>enable

Enters Administration execution mode

 

 

 

 

node#

Response: The prompt in administration execu-

 

 

tion mode is the #

 

 

 

3

node#configure

Enters the Configure configuration mode

 

 

 

 

node(cfg)#

Response: The prompt in the Configure configu-

 

 

ration mode is (cfg)#

 

 

 

4

node(cfg)#context cs

Enters the Context CS configure mode

 

 

 

 

node(ctx-cs)[switch]#

Response: The prompt in the Context CS configu-

 

 

ration mode is (ctx-cs)[switch]#

 

 

 

5

node(ctx-cs)[switch]#interface fxo if-name

Enter the Interface FXO configuration mode

 

 

 

 

node(if-fxo)[if-name]#

Response: The prompt in the Interface FXO con-

 

 

figuration mode is (if-fxo)[if-name]#

 

 

 

6

node(if-fxo)[if-name]#ring-number count

Specifies the number of rings to wait before

 

 

going off-hook. Default = 1 ring.

 

 

 

Example: Configure the ring number to wait for CLID by setting the count to 2. The name of the specific FXO interface is pstn-local.

node>enable

node#configure node(cfg)#context cs

node(ctx-cs)[switch]#interface fxo pstn-local node(if-fxo)[pstn-local]#ring-number 2

You can verify the change in configuration by using the show running-configcommand.

FXO interface configuration task list

421

Page 421
Image 421
Patton electronic SmartNode 4110 Series manual Nodeif-fxo if-name#, Nodeif-fxo if-name #ring-number count