SmartWare Software Configuration Guide

35 • FXS interface configuration

 

 

Configuring ringing-cadence (optional)

The ringing-cadence on FXS Ringing-cadence profiles can be used on FXS interfaces. Each profile consists of a sequence of different rings and ring pauses. Arbitrary ring cadences of up to 10 elements can be configured. The sequence in which the commands are entered (or appear in the config file) defines the sequence in which the corresponding elements are played. If the profile consists of only one element, the element will be repeated forever, causing an endless ring or pause. An empty ringing-cadence will lead to an endless pause.

The profile ringing-cadence must be bound from the respective interface to become effective. Alternatively the profile ringing-cadence default can be modified to modify the ringing-cadence on all FXS interfaces.

Mode: Configure

Step

Command

Purpose

 

 

 

1

[name](cfg)#profile ringing-cadence

Creates a ringing-cadence profile with name name

 

name

and enters ringing-cadence configuration mode.

 

 

 

2

[name](pf-ringingcad)[name]#play

Defines a ring with duration duration.

 

<duration>

 

 

 

 

3

[name](pf-ringingcad)[name]#pause

Defines a pause with duration duration.

 

<duration>

 

 

 

 

4

[name](pf-ringingcad)[name]#...

Repeat step 2 and/or step 3 to define a ringing-

 

 

cadence. If not specified otherwise, the new entries

 

 

are appended to the existing cadence.

 

 

 

5

[name](pf-ringingcad)[name]#flush-ele-

Resets the ringing cadence. Same as deleting and

 

ments

re-creating the profile.

 

 

 

Example: Define an example ringing-cadence

The first line defines the first element of the cadence: 500ms. The second line a pause of 500ms and so on. The cadence is repeated infinitely.

node(cfg)#profile ringing-cadence example node(pf-ringingcad)[example]#play 500 node(pf-ringingcad)[example]#pause 500 node(pf-ringingcad)[example]#play 500 node(pf-ringingcad)[example]#pause 3000

FXS interface configuration task list

407

Page 407
Image 407
Patton electronic SmartNode 4110 Series manual Configuring ringing-cadence optional