Patton electronic SmartNode 4110 Series manual Displaying system image information, Show version

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 69
Image 69

SmartWare Software Configuration Guide

5 • System image handling

 

 

Displaying system image information

This procedure displays information about system images and driver software

Mode: Administrator execution

Step

Command

Purpose

 

 

 

1

show version

Lists the system software release version, information about optional interface

 

 

cards mounted in slots and other information that is the currently running system

 

 

software. If you have just completed a download of new system software from the

 

 

tftp server, you must execute the reload command in order to be running with the

 

 

new system software. This applies equally to driver software.

 

 

 

Example: Display system image information

The following example shows the information that is available for a SmartNode 2000 series device with an optional IC-4BRV interface card mounted in slot 2.

node#show version

Productname

: SN4638/5BIS/UI

Software Version : R3.T 2006-12-04 H323 SIP BRI

Supplier

:

Provider

:

Subscriber

:

Information for Slot 0:

SN4638/5BIS/UI (Admin State: Application Started, Real State:

Application Started)

Hardware

Version

: 1, 3

Serial number

: 00A0BA0209B1

PLD Version

:

0x46010102

Software

Version :

R3.T 2006-12-04 H323 SIP BRI

Copying system images from a network server to Flash memory

As mentioned previously, the system image file contains the application software that runs SmartWare; it is loaded into the flash memory at the Patton Electronics Co. factory. Since most of the voice and data features of the SmartNode are defined and implemented in the application software, upgrading to a new release might be necessary if you want to have additional voice and data features available. A new system image file must be stored permanently into the flash memory of your SmartNode to be present when booting the device.

Since the system image file is preloaded at the Patton Electronics Co. factory, you will have to download a new SmartWare application software only if a major software upgrade is necessary or if recommended by Patton Electronics Co. Under normal circumstances, downloading a system image file should not be needed.

Downloading a new system image file means storing it permanently at a defined location within the Smart- Node flash memory. To store the system image file, you must use a special download script file. This script file defines how to handle the system image file and where to store it. You cannot download any system image file without an appropriate script file.

Each line in the script file is a command for the CLI of your SmartNode. To download a system image file, which will replace the currently running SmartWare application software, a script file with only one command is necessary.

System image handling task list

69

Page 69
Image 69
Patton electronic SmartNode 4110 Series manual Displaying system image information, Show version