52 • VoIP debugging

 

 

 

 

 

----------

 

 

 

 

State:

 

 

REGISTERED

 

Gatekeeper:

 

 

172.16.32.51/1719

 

Allocated Endpoints:

 

0

 

Allocated RAS Engines:

 

1

 

Allocated Control Channels:

 

0

 

Allocated Outgoing Logical Slowstart Channels: 0

 

Allocated Outgoing Logical Faststart Channels: 0

 

Allocated Incoming Logical Channels:

0

 

unit#

 

 

 

 

unit#00:29:03

H323 > [EP h323-00c13dc0] Stack: Allocated new call: 0x00be56b0

00:29:03 H323

> Provider node_33: Added endpoint h323-00c13dc0

 

00:29:03 H323

> [EP h323-00c13dc0] Stack: Dial to remote terminal

 

00:29:03 H323

> [EP h323-00c13dc0]

 

Destination Address:

TEL:60,60

00:29:03 H323

> [EP h323-00c13dc0]

 

Source Address:

TEL:50,50

00:29:03 H323

> [EP h323-00c13dc0]

 

Presentation Indicator:

Presentation

allowed

 

 

 

 

00:29:03 H323 > [EP h323-00c13dc0]

Screening Indicator:

User provided,

not screened

 

 

 

 

00:29:03 H323

> [EP h323-00c13dc0] Information Transfer Capability: Speech

00:29:03 H323

> [EP h323-00c13dc0]

 

Display:

50

00:29:03 H323

> [EP h323-00c13dc0]

 

User-User:

 

00:29:03 H323

> [EP h323-00c13dc0] Set state to TERMINAL TRYING

 

00:29:03 H323

> [EP h323-00c13dc0] State: TERMINAL TRYING, Call Event: PEER CON-

NECTED

 

 

 

 

00:29:03 H323

> [EP h323-00c13dc0] State: TERMINAL TRYING, Call Event: PROGRESS

00:29:03 HRAS

> Stack: Received Admission Confirm

 

00:29:03 H323

> [EP h323-00c13dc0] Stack: State: DIALTONE

 

00:29:03 H323

> [EP h323-00c13dc0] Call-ID is

 

0213:4d80:eacb:11e0:2eee:0030:2b00:1e0e

 

00:29:03 H323

> [EP h323-00c13dc0] Stack: Received Incomplete-Address Indication

00:29:03 H323

> [EP h323-00c13dc0] Stack: State: RINGBACK

 

00:29:03 H323

> [EP h323-00c13dc0] Stack: Received ALERTING

 

00:29:03 H323

> [EP h323-00c13dc0] Progress Indicator: (none)

 

00:29:03 H323

> [EP h323-00c13dc0] State: TERMINAL TRYING, Call Event: TERMINAL

ALERTING

 

 

 

 

00:29:03 H323

> [EP h323-00c13dc0] Set state to TERMINAL ALERTING

 

00:29:08 H323

> [EP h323-00c13dc0] Stack: State: CONNECTED (CALL-SETUP)

00:29:08 H323

> [EP h323-00c13dc0] State: TERMINAL ALERTING, Call Event: TERMINAL

CONNECTED

 

 

 

 

00:29:08 H323

> [EP h323-00c13dc0] Set state to CONNECTED

 

00:29:08 H323

> [EP h323-00c13dc0] Stack: Send STATUS INQUIRY

 

00:29:08 H323

> [EP h323-00c13dc0] Stack: Opening the H.245 control-channel

00:29:08 H323

> [EP h323-00c13dc0] State: CONNECTED, Call Event: PROGRESS

00:29:08 H323

> [EP h323-00c13dc0] Stack: Received STATUS. Audit successful

00:29:08 H323

> [EP h323-00c13dc0] Channel State: IDLE, Channel Event: CONTROL-UP

00:29:08 H323

> [EP h323-00c13dc0] Set channel state to OPENING

 

00:29:08 H323

> [EP h323-00c13dc0] State: CONNECTED, Call Event: PROGRESS

00:29:08 H323

> [EP h323-00c13dc0] Stack: State: CONNECTED (CALL)

 

00:29:08 H323

> [EP h323-00c13dc0] Stack: New Incoming Logical Channel: 00bcca48

00:29:08 H323

> [EP h323-00c13dc0] Channel State: OPENING, Channel Event: MODE-UP

00:29:08 H323

> [EP h323-00c13dc0] Set channel state to UP

 

Debugging call signaling