SmartWare Software Configuration Guide40 • Call router configuration

Mode: Context CS

Step

Command

Purpose

 

 

 

1

node(ctx-cs)[switch]#

Configures the address completion timeout by

 

address-completion timeout timeout

specifying the timeout in seconds. If not config-

 

 

ured, the default address completion timeout is

 

 

12 seconds.

 

 

 

Example: Configure address completion timeout

node[switch]#address-completion timeout 20

Configures the address completion timeout to 20s. A call with an incomplete called party number is dropped 20 seconds after receiving the last called party address update (overlap dialed digit).

Configure default digit collection timeout and terminating character

You can enter called party routing table entries that specify an incomplete number (extended by the T-indica- tor; refer to section “Called party number routing table” on page 466). When the call router selects such an entry, the call router waits for additional digits and starts the digit collection timeout. When the digit collec- tion timeout elapses or when the user enters the terminating character, the call is placed to the destination specified with the routing table entry.

The digit collection timeout has a default value of 5 seconds, the terminating character is the pound character

(#) by default.

Note The digit completion timeout is active when the call router waits for optional digits of a called party number before placing the call to the selected destination. Contrary to this, the address completion timeout, described above, waits for mandatory digits.

Procedure: To configure the digit collection timeout and terminating character

Mode: Context CS

Step

Command

Purpose

 

 

 

1

node(ctx-cs)[switch]#

Configures the digit collection timeout by specify-

 

digit-collection timeout timeout

ing the timeout in seconds. If not configured, the

 

 

default digit collection timeout is 5 seconds.

2

node(ctx-cs)[switch]#

Configures the digit collection terminating charac-

 

digit-collection terminating-char char

ter by specifying the char. This can be any charac-

 

or

ter out of 0123456789*#. The default

 

terminating character is the pound (#). You can

 

no digit-collection terminating-char

 

also use this command in the no-form to disable

 

 

 

 

that the user can stop digit collection by a termi-

 

 

nating character.

 

 

 

Call router configuration task list

462

Page 462
Image 462
Patton electronic SmartNode 4110 Series Example Configure address completion timeout, Address-completion timeout timeout