SmartWare Software Configuration Guide

31 • CS context overview

 

 

We enable DTMF relay and specify codec G.723. (Refer to section “Configuring voice over IP parameters” on page 347).

We define H.323 direct call signaling. (Refer to section “Configuring an H.323 VoIP connection” on page 348).

Configuring general CS settings

First we set clock-source to ISDN port 2/3.

node>enable

node#configure

node(cfg)#system node(sys)#clock-source 2 3 node(sys)#exit node(cfg)#

Configuring call routing

Next we create the ISDN interfaces and configure call routing. Each interface is configured to route all incom- ing calls to the routing table TAB-CALLED-NUMBER. This table is part of the call router and configured below:

node(cfg)#context cs node(ctx-cs)[switch]#interface isdn IF-PBX1

node(if-pstn)[IF-PBX1]#route call dest-table TAB-CALLED-NUMBER node(if-pstn)[IF-PBX1]#exit

node(ctx-cs)[switch]#interface isdn IF-PBX2 node(if-pstn)[IF-PBX2]#route call dest-table TAB-CALLED-NUMBER node(if-pstn)[IF-PBX2]#exit

node(ctx-cs)[switch]#interface isdn IF-PUBLIC-PSTN1 node(if-pstn)[IF-PUBL~]#route call dest-table TAB-CALLED-NUMBER node(if-pstn)[IF-PUBL~]#exit

node(ctx-cs)[switch]#interface isdn IF-PUBLIC-PSTN2 node(if-pstn)[IF-PUBL~]#route call dest-table TAB-CALLED-NUMBER node(if-pstn)[IF-PUBL~]#exit

node(ctx-cs)[switch]#

In addition, we create the two H.323 interfaces and configure call routing, as well as the IP address of the remote H.323 terminal, which is the IP address of the device in office A or office B, respectively.

node(ctx-cs)[switch]#interface h323 IF-COMPOFF-A node(if-h323)[IF-COMP~]#route call dest-table TAB-CALLED-NUMBER node(if-h323)[IF-COMP~]#remoteip 146.86.130.11 node(if-h323)[IF-COMP~]#bind gateway h323 node(if-h323)[IF-COMP~]#exit

node(ctx-cs)[switch]#interface h323 IF-COMPOFF-B node(if-h323)[IF-COMP~]#route dest-table calledNumberRouting node(if-h323)[IF-COMP~]#remoteip 146.86.130.24 node(if-h323)[IF-COMP~]#bind gateway h323 node(if-h323)[IF-COMP~]#exit

node(ctx-cs)[switch]#

Activating CS context configuration

353