16 • PRI port configuration

 

 

Configuring PRI line-build-out (E1T1 in T1 mode only)

The line build out configuration is used in long haul applications to prevent cross talk in the far end device.

Mode: port e1t1 <slot> <port>

Step

Command

Purpose

 

 

 

1

[name] (prt-e1t1)[slot/port]# line-build-

Specifies the pulse attenuation in dB on the line inter-

 

out {0 -7.5 -15 -22.5}

face.

 

 

Restriction: Only available for e1t1 ports in T1

 

 

mode.

 

 

Default for t1: 0 dB

 

 

 

Configuring PRI used-connector (E1T1 in E1 mode only)

If the E1T1 WAN-Card provides several line interface connector types this command specifies which one is currently in use. Sure, the signal is always on all connectors available but dependent on the wiring technology the internal impedance matching must be adapted (RJ45 = 120 Ohm; BNC = 75 Ohm).

Mode: port e1t1 <slot> <port>

Step

Command

Purpose

 

 

 

1

[name] (prt-e1t1)[slot/port]# used-con-

Specifies the currently used connector.

 

nector {bnc rj45}

Restriction: Only available for e1t1 ports in E1

 

 

mode.

 

 

Default for e1: rj45

 

 

 

Configuring PRI application mode (E1T1 only)

The PRI port can be configured to work in either short-haul or in long-haul mode. Short-haulis the default application and should be used for transmission distances up to 180m/600ft. For transmission distances up to 1800m/6000ft, select the long-haulapplication.

Mode: port e1t1 <slot> <port>

Step

Command

Purpose

 

 

 

1

[name] (prt-e1t1)[slot/port]#application

Specifies the e1/t1 application mode

 

{long-haul short-haul}

Restriction: Only available for e1t1 ports

 

 

Default: short-haul

 

 

 